Implementation confirmed that no invalid GatewaySettings instance can exist, so
the factory test's exception fires while evaluating the argument rather than
inside from_settings. Recorded so the test is not misread as the factory
carrying its own validation.
Guards for the three cross-field invariants (source timeout vs lease TTL,
stall window vs max TTFT, probe TTL vs slowest timeout) only ran inside
from_env, so the from_settings path could build a GatewaySettings that
violates the class's own documented invariants. Design moves all of them
plus a non-empty sources check into __post_init__ as _validate_* methods,
matching the existing frozen dataclasses in types.py.
Covers two defects left by PR#1: probe_ttl_s was never moved, and an empty
sources tuple leaked a bare 'max() arg is an empty sequence'.